Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 197
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 103(6): 995-1003, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38662126

RESUMO

BACKGROUND: Limited data exists regarding incidence, progression, and predictors of left atrial appendage (LAA) sealing after transcatheter LAA closure. We aimed to evaluate the incidence, progression, and predictive factors associated with LAA sealing after LAA closure. METHODS: This study includes patients who underwent successful LAA closure with Watchman FLX device and had both pre- and postprocedural computed tomography (CT). Postprocedural CT was performed 45 days after LAA closure and used to evaluate residual LAA patency. Patient who had residual LAA patency at 45 days underwent 1-year follow-up CT. RESULTS: A total of 105 patients (mean age: 75.2 ± 9.6 years; 53.3% female) who underwent successful LAA closure with Watchman FLX device and had pre- and postprocedural CT at 45 days were included. Residual patency was observed in 35 (33.3%) patients: 21 (20.0%) patients showed complete contrast opacification in LAA (complete LAA patency) while 14 (13.3%) patients showed contrast opacification only in the distal LAA (distal LAA patency). Among patients with residual LAA patency at 45 days, the rate of LAA sealing at 1 year was significantly higher in the distal LAA patency group than in the complete LAA patency group (75.0% vs. 16.7%; p = 0.019). Increased depth oversizing was associated with both distal LAA patency and complete LAA patency. CONCLUSION: Postprocedural CT at 45 days detected patent LAA in one-third of patients after LAA closure. LAA sealing was more frequently observed at 1 year among the distal LAA patency group than the complete LAA patency group.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cateterismo Cardíaco , Valor Preditivo dos Testes , Desenho de Prótese , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Feminino , Masculino , Idoso , Idoso de 80 Anos ou mais , Fatores de Risco , Resultado do Tratamento , Fatores de Tempo , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Estudos Retrospectivos , Incidência , Tomografia Computadorizada por Raios X , Tomografia Computadorizada Multidetectores
2.
Pharmacoepidemiol Drug Saf ; 33(4): e5786, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38565524

RESUMO

PURPOSE: Among patients with atrial fibrillation (AF), a nonpharmacologic option (e.g., percutaneous left atrial appendage occlusion [LAAO]) is needed for patients with oral anticoagulant (OAC) contraindications. Among beneficiaries in the Medicare fee-for-service coverage 20% sample databases (2015-18) who had AF and an elevated CHA2DS2-VASc score, we assessed the association between percutaneous LAAO versus OAC use and risk of stroke, hospitalized bleeding, and death. METHODS: Patients undergoing percutaneous LAAO were matched to up to five OAC users by sex, age, date of enrollment, index date, CHA2DS2-VASc score, and HAS-BLED score. Overall, 17 156 patients with AF (2905 with percutaneous LAAO) were matched (average ± SD 78 ± 6 years, 44% female). Cox proportional hazards model were used. RESULTS: Median follow-up was 10.3 months. After multivariable adjustments, no significant difference for risk of stroke or death was noted when patients with percutaneous LAAO were compared with OAC users (HRs [95% CIs]: 1.14 [0.86-1.52], 0.98 [0.86-1.10]). There was a 2.94-fold (95% CI: 2.50-3.45) increased risk for hospitalized bleeding for percutaneous LAAO compared with OAC use. Among patients 65 to <78 years old, those undergoing percutaneous LAAO had higher risk of stroke compared with OAC users. No association was present in those ≥78 years. CONCLUSION: In this analysis of real-world AF patients, percutaneous LAAO versus OAC use was associated with similar risk of death, nonsignificantly elevated risk of stroke, and an elevated risk of bleeding in the post-procedural period. Overall, these results support results of randomized trials that percutaneous LAAO may be an alternative to OAC use for patients with contraindications.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Feminino , Idoso , Estados Unidos/epidemiologia , Masculino , Apêndice Atrial/cirurgia , Resultado do Tratamento , Medicare , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Fibrilação Atrial/complicações , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/induzido quimicamente , Anticoagulantes/efeitos adversos
3.
Arch Cardiovasc Dis ; 117(4): 283-296, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38490844

RESUMO

Atrial cardiomyopathy is defined as any complex of structural, architectural, contractile or electrophysiological changes affecting atria, with the potential to produce clinically relevant manifestations. Most of our knowledge about the mechanistic aspects of atrial cardiomyopathy is derived from studies investigating animal models of atrial fibrillation and atrial tissue samples obtained from individuals who have a history of atrial fibrillation. Several noninvasive tools have been reported to characterize atrial cardiomyopathy in patients, which may be relevant for predicting the risk of incident atrial fibrillation and its related outcomes, such as stroke. Here, we provide an overview of the pathophysiological mechanisms involved in atrial cardiomyopathy, and discuss the complex interplay of these mechanisms, including aging, left atrial pressure overload, metabolic disorders and genetic factors. We discuss clinical tools currently available to characterize atrial cardiomyopathy, including electrocardiograms, cardiac imaging and serum biomarkers. Finally, we discuss the clinical impact of atrial cardiomyopathy, and its potential role for predicting atrial fibrillation, stroke, heart failure and dementia. Overall, this review aims to highlight the critical need for a clinically relevant definition of atrial cardiomyopathy to improve treatment strategies.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cardiomiopatias , Acidente Vascular Cerebral , Animais , Humanos , Fibrilação Atrial/diagnóstico , Átrios do Coração , Cardiomiopatias/diagnóstico , Cardiomiopatias/terapia
4.
Circ Cardiovasc Qual Outcomes ; 17(3): e010279, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38440888

RESUMO

BACKGROUND: Transcatheter left atrial appendage occlusion (LAAO) is an alternative to oral anticoagulants (OACs) for stroke prevention in patients with atrial fibrillation, but the predictors of LAAO use in routine care are unclear. We aimed to assess the utilization trends of LAAO and compare the change in characteristics of LAAO users versus OACs since its marketing. METHODS: Using the US Medicare claims database (March 15, 2015, to December 31, 2020), we identified patients with atrial fibrillation, ≥65 years, and CHA2DS2-VASc score ≥2 (men) or ≥3 (women), with either first implantation of an LAAO device or initiation of OACs, including apixaban, dabigatran, rivaroxaban, edoxaban, or warfarin. Patient characteristics, measured 365 days before the first LAAO or OAC use date, were compared using logistic regression. RESULTS: There were 30 058 LAAO recipients (mean age, 77.74 years; female, 42.1%) and 792 600 OAC initiators (mean age, 78.48; female, 53.3%). In 2020, patients had higher odds of initiating LAAO use than in 2015 (0.52 versus 9.32%; adjusted odds ratio [aOR], 13.64 [95% CI, 12.56-14.81]). Old age (ie, >85 versus 65-75 years; aOR, 0.84 [95% CI, 0.80-0.88]), female sex (aOR, 0.74 [95% CI, 0.71-0.76]), Black race (aOR, 0.63 [95% CI, 0.58-0.68]) versus White race, and Medicaid eligibility (aOR, 0.61 [95% CI, 0.58-0.64]) were associated with lower odds of receiving LAAO. Among clinical characteristics, frailty, cancer, fractures, and venous thromboembolism were associated with lower odds of LAAO use, while history of intracranial and extracranial bleeding, coagulopathy, and falls were associated with higher odds of receiving LAAO. CONCLUSIONS: Among patients with atrial fibrillation receiving stroke-preventive therapy, LAAO use increased rapidly from 2015 to 2020 and was positively associated with the risk factors for OAC complications but negatively associated with old age, advanced frailty, and cancer. Black race and female sex were associated with a lower likelihood of receiving LAAO.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Fragilidade , Neoplasias , Acidente Vascular Cerebral , Masculino , Humanos , Feminino , Idoso , Estados Unidos/epidemiologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/epidemiologia , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Medicare , Anticoagulantes/efeitos adversos , Neoplasias/induzido quimicamente , Resultado do Tratamento
6.
J Cardiovasc Electrophysiol ; 35(3): 389-398, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38192059

RESUMO

INTRODUCTION: This study was performed to explore the diagnostic value of cardiac computed tomography angiography (CCTA) for endothelial insufficiency (EIS) of a left atrial appendage (LAA) disc-like occluder. METHODS: Fifty-nine patients with nonvalvular atrial fibrillation who underwent placement of an LAA disc-like occluder (LAmbre; Lifetech Scientific) in our hospital were retrospectively analyzed. Patients who were found to have contrast agent entering the LAA at the 3-month postoperative CCTA examination underwent Hounsfield unit (HU) measurement of the LAA and construction of a three-dimensional (3D) model of the device for preliminary discernment between peri-device leakage (PDL) and EIS. These patients were then further examined by transesophageal echocardiography (TEE) to check for concordance with the computed tomography (CT) findings. According to the CT and TEE results, all patients were divided into the PDL group, total endothelialization group, and EIS group. The endothelial conditions and other implantation-related results were also tracked at the 6-month follow-up. RESULTS: All 59 patients underwent successful implantation of the LAmbre LAA closure device with no severe adverse events during the procedure. Thirty-five patients were found to have contrast agent entering the LAA at the 3-month postoperative CCTA follow-up. Based on the CT HU measurement and the 3D construction analysis results, these 35 patients were divided into the PDL group (19 patients) and the EIS group (16 patients). In the PDL group, the contrast agent infiltrated from the shoulder along the periphery of the occluder on two-dimensional (2D) CT images, and the 3D model showed a gap between the LAA and the device cover. However, the CCTA images of the other 16 patients in the EIS group showed that the contrast agent in the occluder on the 2D CTA images and 3D construction model confirmed the absence of a gap between the LAA and the device cover. TEE confirmed all of the CT results. The 6-month follow-up results showed that 14 of 19 patients in the EIS group achieved total endothelialization, whereas this number in the PDL group was only five of 19 patients. CONCLUSION: CCTA can replace TEE for examination of the endothelialization status, and patients with EIS have a higher chance of endothelialization than patients with PDL.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Humanos , Angiografia por Tomografia Computadorizada/métodos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Estudos Retrospectivos , Meios de Contraste , Tomografia Computadorizada por Raios X , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Ecocardiografia Transesofagiana/métodos , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento
7.
Cardiovasc Revasc Med ; 58: 45-49, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37393190

RESUMO

PURPOSE: Explore gender disparities in patients undergoing transseptal puncture (TSP) for selected transcatheter cardiac intervention procedures. METHODS: Patients who underwent TSP from January 2015 through September 2021 were reviewed. Primary outcomes were procedural and in-hospital major adverse events. Secondary endpoints were procedural success and hospitalization length of stay (LOS) >1 day. Unadjusted and multivariable-adjusted logistic regression analyses were performed to assess gender differences for in-hospital adverse events. RESULTS: The study cohort comprised 510 patients (mean [SD] age, 74 [14.0] years); 246 women (48 %) underwent TSP for left atrial appendage occlusion (LAAO) or transcatheter edge-to-edge-repair (TEER). Compared with men, women were younger, had higher CHA2DS2-VASc scores, and were more likely to have had a prior ischemic stroke, but were less likely to have paroxysmal atrial fibrillation. After multivariable adjustment, there were no differences between genders in aborted or canceled procedures (odds ratio [OR]: 0.43; 95 % confidence interval [CI]: 0.10-1.96; p = 0.277), any adverse events (OR: 1.00; 95 % CI: 0.58-1.70; p = 0.98), major adverse events (OR: 1.60; 95 % CI: 0.90-2.80; p = 0.11), or death (OR: 1.00; 95 % CI: 0.20-5.00; p = 0.31). Subgroup analysis for LAAO procedures showed that at 30 days, women had higher rates of adverse events, major adverse cardiac events, and LOS >1 day. CONCLUSIONS: Men and women showed no differences in procedural success and in-hospital adverse outcomes in unadjusted analysis and after multivariable adjustment, despite women having a higher risk profile among patients undergoing TSP. However, compared with men, women undergoing LAAO experienced a higher rate of in-hospital adverse events irrespective of TSP.


Assuntos
Apêndice Atrial , Fibrilação Atrial , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Masculino , Feminino , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Fibrilação Atrial/complicações , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , AVC Isquêmico/etiologia , Fatores de Tempo , Resultado do Tratamento , Acidente Vascular Cerebral/etiologia
9.
J Vet Cardiol ; 51: 145-156, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38128420

RESUMO

INTRODUCTION/OBJECTIVES: Veterinary echocardiographers' preferences for left atrial (LA) size assessment in cats have not been systematically investigated. The primary aim of this prospective exploratory study was to investigate echocardiographers' preferences concerning LA size assessment in cats. A secondary aim was to investigate echocardiographers' preferences for assessing LA size in subgroups based on geographic, demographic, and professional profiles. ANIMALS, MATERIALS, AND METHODS: An online survey instrument was designed, verified, and distributed globally to veterinary echocardiographers. RESULTS: A total of 655 veterinary echocardiographers from six continents and 54 countries, working in specialty practice (56%) and in general practice (38%), provided data. Linear two-dimensional (2D) technique was favored by most echocardiographers (n = 612) for LA size assessment. Most commonly, respondents combined linear 2D with subjective assessment (n = 227), while 209 used linear 2D-based methods alone. Most echocardiographers using linear 2D-based methods preferred the right parasternal short-axis view and to index the LA to the aorta (Ao). Approximately 10% of the respondents obtained LA dimensions from a right parasternal long-axis four-chamber view. Approximately one-third of echocardiographers that made linear measurements from 2D echocardiograms shared the same preferences regarding cat position, acquisition view, indexing method and time point identification for the LA measurement. The responses were comparably homogeneous across geographic location, level of training, years performing echocardiography, and type of practice. DISCUSSION/CONCLUSION: Most veterinary echocardiographers assessed LA size in cats using linear 2D echocardiography from a right parasternal short-axis view, and indexed LA to Ao. Respondents' preferences were similar over geographic, demographic, and professional backgrounds.


Assuntos
Apêndice Atrial , Átrios do Coração , Gatos , Animais , Estudos Prospectivos , Átrios do Coração/diagnóstico por imagem , Ecocardiografia/veterinária , Ecocardiografia/métodos , Aorta
10.
J Vet Cardiol ; 51: 157-171, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38128421

RESUMO

INTRODUCTION/OBJECTIVES: Veterinary echocardiographers' preferences for left atrial (LA) size assessment in dogs have never been systematically investigated. The primary aim of this international survey study was to investigate echocardiographers' preferences for LA size assessment in dogs. The secondary aim was to investigate echocardiographers' preferences for assessing LA size in subgroups based on geographic, demographic, and professional profiles. ANIMALS, MATERIALS, AND METHODS: An online survey instrument was designed, verified, and distributed globally to the veterinary echocardiographers. RESULTS: A total of 670 echocardiographers from 54 countries on six continents completed the survey. Most echocardiographers (n = 621) used linear two-dimensional (2D)-based methods to assess LA size, 379 used subjective assessment, and 151 used M-mode-based methods. Most commonly, echocardiographers combined linear 2D-based methods with subjective assessment (n = 222), whereas 191 used linear 2D-based methods alone. Most echocardiographers (n = 436) using linear 2D-based methods preferred the right parasternal short-axis view and indexed the LA to the aorta. Approximately 30% (n = 191) of the echocardiographers who performed linear measurements from 2D echocardiograms shared the same preferences regarding dog position, acquisition view, indexing method, and identification of the time-point used for the measurement. The responses were comparably homogeneous across geographic location, training level, years of performing echocardiography, and type of practice. DISCUSSION/CONCLUSION: Most veterinary echocardiographers assessed LA size in dogs using linear 2D echocardiography from a right parasternal short-axis view, and by indexing the LA to the aorta. The respondents' preferences were similar across geographic, demographic, and professional backgrounds.


Assuntos
Apêndice Atrial , Átrios do Coração , Cães , Animais , Átrios do Coração/diagnóstico por imagem , Ecocardiografia/veterinária , Ecocardiografia/métodos , Aorta/diagnóstico por imagem
11.
J Med Econ ; 26(1): 1357-1367, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37819734

RESUMO

AIMS: Left atrial appendage closure (LAAC) has been demonstrated to be cost-saving relative to oral anticoagulants for stroke prophylaxis in patients with non-valvular atrial fibrillation (NVAF) in the United States and Europe. This study assessed the cost-effectiveness of LAAC with the Watchman device relative to warfarin and direct oral anticoagulants (DOACs) for stroke risk reduction in NVAF from a Japanese public healthcare payer perspective. METHODS: A Markov model was developed with 70-year-old patients using a lifetime time horizon. LAAC clinical inputs were from pooled, 5-year PROTECT AF and PREVAIL trials; warfarin and DOAC inputs were from published meta-analyses. Baseline stroke and bleeding risks were from the SALUTE trial on LAAC. Cost inputs were from the Japanese Medical Data Vision database. Probabilistic and one-way sensitivity analyses were performed. RESULTS: Over the lifetime time horizon, LAAC was less costly than warfarin (savings of JPY 1,878,335, equivalent to US $17,600) and DOACs (savings of JPY 1,198,096, equivalent to US $11,226). LAAC also provided 1.500 more incremental quality-adjusted life years (QALYs) than warfarin and 0.996 more than DOACs. In probabilistic sensitivity analysis, LAAC was cost-effective relative to warfarin and DOACs in 99.98% and 99.73% of simulations, respectively. LAAC dominated (had higher cumulative QALYs and was less costly than) warfarin and DOACs in 89.94% and 83.35% of simulations, respectively. CONCLUSIONS: Over a lifetime time horizon, LAAC is cost-saving relative to warfarin and DOACs for stroke risk reduction in NVAF patients in Japan and is associated with improved quality-of-life.


This study examined the cost-effectiveness of left atrial appendage closure (LAAC) compared to oral anticoagulants for stroke risk reduction among individuals with a specific type of irregular heart rhythm called non-valvular atrial fibrillation (NVAF). This study evaluated the cost-effectiveness of LAAC using the Watchman device in comparison to warfarin and direct oral anticoagulants (DOACs) from the perspective of Japan's public healthcare system. To investigate this, a computer-based model was developed involving 70-year-old patients over their lifetime. Data from notable studies such as the PROTECT AF and PREVAIL trials (covering 5 years) for LAAC and published meta-analyses for warfarin and DOACs were incorporated into the model. Baseline stroke and bleeding risks were derived from the SALUTE trial on LAAC. Cost inputs were based on data from the Japanese Medical Data Vision database. Additionally, we performed thorough cost-effectiveness analyses, including probabilistic and one-way sensitivity assessments. Our findings revealed that, over a lifetime, LAAC was more cost-effective than both warfarin and DOACs. Further, LAAC contributed an additional 1.500 quality-adjusted life years (QALYs) compared to warfarin and 0.996 QALYs compared to DOACs. In the long-term, adopting LAAC as an alternative to warfarin and DOACs is a cost-effective strategy for reducing stroke risk in NVAF patients in Japan. Moreover, it is associated with enhanced quality-of-life. These findings hold significant implications for informing decision-making in healthcare policies and clinical practices for NVAF patients.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Varfarina/uso terapêutico , Análise Custo-Benefício , Japão , Apêndice Atrial/cirurgia , Anticoagulantes/uso terapêutico , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/complicações , Resultado do Tratamento
14.
J Am Soc Echocardiogr ; 36(10): 1083-1091, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37307939

RESUMO

BACKGROUND: Contrast-enhanced computed tomography is the reference-standard imaging technique to assess left atrial appendage (LAA) morphology. The aim of this study was to evaluate the accuracy and reliability of two-dimensional and new three-dimensional (3D) transesophageal echocardiographic rendering modalities in assessing LAA morphology. METHODS: Seventy consecutive patients who underwent both computed tomography and transesophageal echocardiography (TEE) were retrospectively enrolled. The traditional LAA morphology classification system (LAAcs; chicken wing, cauliflower, cactus, and windsock) and a new simplified LAAcs based on the LAA bend angle were used for the analysis. LAA morphology was independently assessed by two trained readers using three different modalities: two-dimensional TEE, 3D TEE with multiplanar reconstruction, and a new 3D transesophageal echocardiographic rendering modality with improved transparency (Glass). The new LAAcs and traditional LAAcs were compared in terms of intra- and interrater reliability. RESULTS: With the new LAAcs, two-dimensional TEE was fairly accurate in identifying LAA morphology (κ = 0.43, P < .05), with moderate interrater (κ = 0.50, P < .05) and substantial intrarater (κ = 0.65, P < .005) agreement. Three-dimensional TEE showed higher accuracy and reliability: 3D TEE with multiplanar reconstruction had almost perfect accuracy (κ = 0.85, P < .001) and substantial (κ = 0.79, P < .001) interrater reliability, while 3D TEE with Glass had substantial accuracy (κ = 0.70, P < .001) and almost perfect (κ = 0.84, P < .001) interrater reliability. Intrarater agreement was almost perfect for both 3D transesophageal echocardiographic modalities (κ = 0.85, P < .001). Accuracy was considerably lower when the traditional LAAcs was used, with 3D TEE with Glass being the most reliable technique (κ = 0.75, P < .05). The new LAAcs showed higher inter- and intrarater reliability compared with the traditional LAAcs (interrater, κ = 0.85 vs κ = 0.49; intrarater, κ = 0.94 vs κ = 0.68; P < .05). CONCLUSIONS: Three-dimensional TEE is an accurate, reliable, and feasible alternative to computed tomography in assessing LAA morphology with the new LAAcs. The new LAAcs shows higher reliability rates than the traditional one.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Humanos , Ecocardiografia Transesofagiana/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
15.
J Am Heart Assoc ; 12(10): e028716, 2023 05 16.
Artigo em Inglês | MEDLINE | ID: mdl-37183832

RESUMO

Background The LAAOS III (Left Atrial Appendage Occlusion Study) clinical trial demonstrated that concomitant left atrial appendage (LAA) occlusion leads to a lower risk of ischemic stroke or systemic embolism compared with no occlusion in participants with atrial fibrillation and a CHA2DS2-VASc score of ≥2 undergoing cardiac surgery for another indication. We report the cost implications of concomitant LAA occlusion during cardiac surgery. Methods and Results Using LAAOS III data, we compared the costs (in US dollars) associated with LAA occlusion to no occlusion from the perspective of the Centers for Medicare and Medicaid Services. We calculated the average cost per participant during the trial by applying Medicare reimbursement costs to cardiovascular events for all trial participants. We conducted sensitivity analyses, varying the cost of stroke ±25% and occlusion technique use. Cost neutrality was defined as a mean cost difference within ±5% of the cost per participant in the no-occlusion group. Total study cost per participant was $3878 in the LAA occlusion group and $4490 in the no-occlusion group, a mean difference of -$612 (95% CI, -$1276 to $45). The main drivers of cost savings were fewer stroke events during the trial (mean difference of -$1021). In sensitivity analyses, LAA occlusion was cost saving for suture and stapler techniques but more expensive with closure device. Conclusions Concomitant LAA occlusion was cost saving for participants in LAAOS III. Our findings support concomitant LAA occlusion as an economically dominant strategy for patients with atrial fibrillation and a CHA2DS2-VASc score of ≥2 undergoing cardiac surgery.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Acidente Vascular Cerebral , Estados Unidos/epidemiologia , Humanos , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Apêndice Atrial/cirurgia , Medicare , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/complicações , Custos e Análise de Custo , Resultado do Tratamento
16.
Indian Heart J ; 75(2): 133-138, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36894122

RESUMO

CONTEXT: Complex left atrial appendage (LAA) morphology is increasingly associated with cryptogenic ischemic stroke as compared to cardioembolic stroke due to atrial fibrillation (AF). However, data on such an association in patients with other etiological stroke subtypes in the absence of AF is limited. AIM: The study aimed to assess the LAA morphology, dimension and other echocardiographic parameters by transesophageal echocardiography (TEE) in patients with embolic stroke of undetermined source (ESUS) and compare it with other etiological stroke subtypes without known AF. METHODS: This was a single-Centre, observational study involving comparison of echocardiographic parameters including LAA morphology and dimension in ESUS patients (group A; n = 30) with other etiological stroke subtypes i.e., TOAST (Trial of Org 10172 in Acute Stroke Treatment) class I-IV without AF (group B; n = 30). RESULTS: Complex LAA morphology was predominant in group A (18 patients in group A versus 5 patients in group B, p-Value = 0.001). Mean LAA orifice diameter (15.3 + 3.5 mm in group A versus 17 + 2.0 mm in group B, p-Value = 0.027) and LAA depth were significantly lower in group A (28.4 + 6.6 mm in group A versus 31.7 + 4.3 mm in group B, p-Value = 0.026). Out of these three parameters only complex LAA morphology was found to be independently associated with ESUS [OR = 6.003, 95% CI {1.225-29.417}, p = 0.027]. CONCLUSION: Complex LAA morphology is a predominant feature in ischemic stroke patients with ESUS and may contribute to an increased risk of stroke in these patients.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Ecocardiografia Transesofagiana , Apêndice Atrial/diagnóstico por imagem , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia
17.
JACC Cardiovasc Interv ; 16(6): 627-642, 2023 03 27.
Artigo em Inglês | MEDLINE | ID: mdl-36990553

RESUMO

Left atrial appendage occlusion is an increasingly adopted stroke prevention strategy in patients with atrial fibrillation. However, peridevice leaks after the procedure are not infrequent and have recently been shown to confer a higher risk for subsequent ischemic events. In this paper, the authors review the available research on the frequency, mechanisms, clinical significance, and management of peridevice leak after percutaneous left atrial appendage occlusion.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Incidência , Apêndice Atrial/diagnóstico por imagem , Resultado do Tratamento , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Cateterismo Cardíaco/efeitos adversos
18.
Heart Fail Rev ; 28(5): 1177-1187, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36800057

RESUMO

The left atrial appendage (LAA) is considered not only to be the most frequent site of thrombus formation, but also to play a pivotal role in maintaining normal cardiac function. Transesophageal echocardiography (TEE) is widely used to assess LAA function. The LAA flow velocity has been used as a surrogate for LAA function, and it varies with multiple interrelated factors including age, hemodynamics, type of arrhythmia, and antiarrhythmic interventions. Relatively great importance of LAA function is involved with intraatrial thrombus formation and subsequent thromboembolism, and thus, understanding of characteristics and behaviors of the LAA under various clinical conditions may help determine strategies against atrial thrombosis. Also, techniques other than TEE-derived Doppler to assess LAA function, such as tissue Doppler imaging, have been proposed. In this review, we introduce clinical and echocardiographic correlates of LAA function, the LAA flow velocity in particular, its significance, and how to interpret functional patterns of the LAA each relevant to specific clinical settings.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Trombose , Humanos , Fibrilação Atrial/diagnóstico por imagem , Apêndice Atrial/diagnóstico por imagem , Ecocardiografia , Ecocardiografia Transesofagiana/métodos , Trombose/diagnóstico por imagem
19.
Circulation ; 147(7): 586-596, 2023 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-36780379

RESUMO

BACKGROUND: The comparative real-world outcomes of older patients with atrial fibrillation (AF) treated with anticoagulation compared with left atrial appendage occlusion (LAAO) may be different from those in clinical trials because of differences in anticoagulation strategies and patient demographics, including a greater proportion of women. We sought to compare real-world outcomes between older patients with AF treated with anticoagulation and those treated with LAAO by sex. METHODS: Using Medicare claims data from 2015 to 2019, we identified LAAO-eligible beneficiaries and divided them into sex subgroups. Patients receiving LAAO were matched 1:1 to those receiving anticoagulation alone through propensity score matching. The risks of mortality, stroke or systemic embolism, and bleeding were compared between matched groups with adjustment for potential confounding characteristics in Cox proportional hazards models. RESULTS: Among women, 4085 LAAO recipients were matched 1:1 to those receiving anticoagulation; among men, 5378 LAAO recipients were similarly matched. LAAO was associated with a significant reduction in the risk of mortality for women and men (hazard ratio [HR], 0.509 [95% CI, 0.447-0.580]; and HR, 0.541 [95% CI, 0.487-0.601], respectively; P<0.0001), with a similar finding for stroke or systemic embolism (HR, 0.655 [95% CI, 0.555-0.772]; and HR, 0.649 [95% CI, 0.552-0.762], respectively; P<0.0001). Bleeding risk was significantly greater in LAAO recipients early after implantation but lower after the 6-week periprocedural period for women and men (HR, 0.772 [95% CI, 0.676-0.882]; and HR, 0.881 [95% CI, 0.784-0.989], respectively; P<0.05). CONCLUSIONS: In a real-world population of older Medicare beneficiaries with AF, compared with anticoagulation, LAAO was associated with a reduction in the risk of death, stroke, and long-term bleeding among women and men. These findings should be incorporated into shared decision-making with patients considering strategies for reduction in AF-related stroke.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Embolia , Acidente Vascular Cerebral , Masculino , Humanos , Feminino , Idoso , Estados Unidos/epidemiologia , Apêndice Atrial/cirurgia , Medicare , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Hemorragia/epidemiologia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Embolia/epidemiologia , Anticoagulantes/efeitos adversos , Resultado do Tratamento
20.
J Am Heart Assoc ; 12(5): e028032, 2023 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-36802837

RESUMO

Background Inequitable access to high-technology therapeutics may perpetuate inequities in care. We examined the characteristics of US hospitals that did and did not establish left atrial appendage occlusion (LAAO) programs, the patient populations those hospitals served, and the associations between zip code-level racial, ethnic, and socioeconomic composition and rates of LAAO among Medicare beneficiaries living within large metropolitan areas with LAAO programs. Methods and Results We conducted cross-sectional analyses of Medicare fee-for-service claims for beneficiaries aged 66 years or older between 2016 and 2019. We identified hospitals establishing LAAO programs during the study period. We used generalized linear mixed models to measure the association between zip code-level racial, ethnic, and socioeconomic composition and age-adjusted rates of LAAO in the most populous 25 metropolitan areas with LAAO sites. During the study period, 507 candidate hospitals started LAAO programs, and 745 candidate hospitals did not. Most new LAAO programs opened in metropolitan areas (97.4%). Compared with non-LAAO centers, LAAO centers treated patients with higher median household incomes (difference of $913 [95% CI, $197-$1629], P=0.01). Zip code-level rates of LAAO procedures per 100 000 Medicare beneficiaries in large metropolitan areas were 0.34% (95% CI, 0.33%-0.35%) lower for each $1000 zip code-level decrease in median household income. After adjustment for socioeconomic markers, age, and clinical comorbidities, LAAO rates were lower in zip codes with higher proportions of Black or Hispanic patients. Conclusions Growth in LAAO programs in the United States had been concentrated in metropolitan areas. LAAO centers treated wealthier patient populations in hospitals without LAAO programs. Within major metropolitan areas with LAAO programs, zip codes with higher proportions of Black and Hispanic patients and more patients experiencing socioeconomic disadvantage had lower age-adjusted rates of LAAO. Thus, geographic proximity alone may not ensure equitable access to LAAO. Unequal access to LAAO may reflect disparities in referral patterns, rates of diagnosis, and preferences for using novel therapies experienced by racial and ethnic minority groups and patients experiencing socioeconomic disadvantage.


Assuntos
Apêndice Atrial , Medicare , Humanos , Idoso , Estados Unidos/epidemiologia , Etnicidade , Apêndice Atrial/cirurgia , Estudos Transversais , Grupos Minoritários , Renda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA